17. FULLY CLOSED LOOP SYSTEM 
17 -  16 
 
(7)  Setting of fully closed loop dual feedback filter 
With the initial value (setting = 10) set in [Pr. PE08 Fully closed loop dual feedback filter the dual 
feedback filter], make gain adjustment by auto tuning, etc. as in semi closed loop control. While 
observing the servo operation waveform with the graph function, etc. of MR Configurator2, adjust the 
dual feedback filter. 
 
The dual feedback filter operates as described below depending on the setting. 
 
[Pr. PE08] setting  Control mode  Vibration  Settling time 
1 
to 
4499 
Dual feedback 
Seldom occurs 
to 
Frequently occurs 
Long time 
to 
Short time 
4500  Fully closed loop     
 
Increasing the dual feedback filter setting shortens the settling time, but increases servo motor vibration 
since the motor is more likely to be influenced by the load-side encoder vibration. The maximum setting 
of the dual feedback filter should be less than half of the PG2 setting. 
 
Reduction of settling time: Increase the dual feedback filter setting. 
Droop pulses
Command
Droop pulses
Command
TimeTime
 
Suppression of vibration: Decrease the dual feedback filter setting. 
Droop pulses
Command
Droop pulses
Command
TimeTime