METER LOCATION, ORIENTATION AND APPLICATIONS
The M1000 provides two amplifier mounting options: an integral or meter mount option and a junction box/remote option.
Figure 6: Meter mount amplifier Figure 7: Junction box with remote amplifier
Temperature Ranges
TO PREVENT DAMAGE TO THE METER, STRICTLY OBSERVE THE MAXIMUM TEMPERATURE RANGES OF THE AMPLIFIER
AND DETECTOR.
AFIN D'ÉVITER TOUT DOMMAGE AU COMPTEUR, RESPECTEZ RIGOUREUSEMENT LES PLAGES DE TEMPÉRATURES
MAXIMALES DE L'AMPLIFICATEUR ET DU DÉTECTEUR.
• In regions with extremely high ambient temperatures, it is recommended to protect the amplifier from direct sunlight.
• In cases where fluid temperature exceeds 212° F (100° C), use the remote version.
Amplifier Ambient temperature –4…140° F (–20…60° C)
Detector Fluid temperature
PTFE / PFA –40…302° F (–40…150° C)
Hard rubber 32…176° F (0…80° C)
Soft Rubber 32…176° F (0…80° C)
Meter Location, Orientation and Applications
Page 9 March 2020 MAG-UM-00379-EN-07