Material | Aluminum |
---|---|
Length Options | Customizable |
Installation | Ceiling-mounted |
Configuration | Straight, curved |
Lifting Speed | Dependent on the hoist used with the rail system |
Noise Level | Low (specific dB not specified) |
Safety Features | Emergency stop, overload protection |
Only authorized personnel can perform installation and issue certificates.
Importance of site survey for planning installation, documenting conditions and logistics.
Details mounting based on ceiling and wall materials and structural design.
Specifies minimum attachment points, pullout force requirements, and load calculations.
Recommended working heights, lifting intervals, and floor-to-suspension distances.
Maximum distances between attachments for ceiling mounted systems based on SWL.
Maximum distances for wall mounted systems based on SWL and rail profile.
Procedure for load testing a straight rail system, including lift height and travel.
Procedure for load testing a traverse rail system across primary and secondary rails.