♦ Routing Plug / EEPROM mode “E”
The SR5 allows you to change from EEPROM mode (factory programmed
sorting configurations) to routing plug mode and from routing plug mode to
EEPROM mode.
To set this option, ensure that the SR5 is powered up through the main parallel
connector. Changes cannot be made in serial mode.
NB: Make a note of the rotary switch position and the bank select switch
positions.
Turn the rotary switch to position E.
Set Bank Select switch 1, to the desired position.
When the desired switch positions are selected press and hold the program
button, (situated underneath the rotary switch), the LED will change from Green
to Red, release the program button; the LED will change back to Green.
NB: If the LED stays Green then Routing Plug / EEPROM mode “E” is not
available.
Return the rotary switch and the Bank Select switches to their original positions.
Press the program button, the LED will change to Red, release the program
button; the LED will change back to Green.
NB: NEVER leave the validator with the rotary switch in positions D,E or F.
Not UsedRouting Plug Mode
EEPROM Mode Not Used