SR5 Technical Manual TSP010.doc Issue 3.0 - October 2001
CONFIDENTIAL
Not to be disclosed without prior written permission from Money Controls
Page 45 of 50
Specified EMC Performance
Emissions
This product is compliant with EMC test specification EN55022; 1998
Immunity
This product is compliant with EMC test specification EN55014-2; 1997
Shock / Vibration Immunity
This product is compliant with BS 2011 part 2.1. [ IEC 68-2-27 ]
Environmental specification
Table 14: Environmental Ranges
Operating temperature range:
0°C to 55°C 10% to 75%
RH non-condensing
Storage temperature range:
-20°C to 70°C 5% to 95%
RH non-condensing
(Recovery time by the acceptor after a temperature step change is 1
hour per 20°C. Maximum operating rate of change 20°C per hour.)
Material Flammability Rating
The major plastic part of the SR5 (the body) is rated as UL94-V0
The other parts are rated as UL94-HB
The 8-way manifold is rated as UL94-HB