8.8.3 Fuel prefilter (non-switchable) – Draining
DANGER
Components are moving or rotating.
Risk of crushing, danger of parts of the body being caught or pulled in!
Operate the engine at low load only. Keep clear of the danger zone of the engine.
WARNING
Fuels are combustible and explosive.
Risk of fire and explosion!
Avoid open flames, electrical sparks and ignition sources.
Do not smoke.
Wear protective clothing, protective gloves, and safety glasses / facial protection.
WARNING
Liquid or gaseous media, e.g. fuel, are poisonous.
Escaping vapors of highly volatile media, e.g. fuel or ether.
Risk of fatal injury through swallowing; risk of poisoning through inhalation; irritation to eyes
and skin!
Seek medical attention immediately; do not induce vomiting.
Do not inhale vapors or mist.
Wear protective clothing, protective gloves, and safety glasses.
If contact is made with skin, wash off with water and soap.
WARNING
Exhaust gases are harmful to health and may cause cancer.
Risk of poisoning and suffocation!
Keep the engine room well-ventilated at all times.
Repair leaking exhaust pipework immediately.
WARNING
High level of engine noise when the engine is running.
Risk of damage to hearing!
Wear ear protectors.
WARNING
Fuel in the prefilter can be pressurized.
Risk of injury through spraying fuel!
Wear protective gloves and eye protectors/safety mask.
Open screw-coupling slowly.
Preparatory steps
u Pressure ratios in the fuel prefilter, see (→ Page 148).
In case of low pressure, drain fuel prefilter according to version A, see (→ Page 143).
In case of high pressure, drain fuel prefilter according to version B, see (→ Page 144).
Draining fuel prefilter with low pressure, version A
Note: The fuel prefilter must only be drained with the engine at a standstill!
1. Provide a suitable container to collect the water.
2. Stop engine and disable engine start.
3. Close fuel supply if a shutoff valve is available.
MS15054/03E 2018-07
| Fuel Filter | 143
TIM-ID: 0000066428 - 005

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTU 12V2000Gx6 series and is the answer not in the manual?

MTU 12V2000Gx6 series Specifications

General IconGeneral
BrandMTU
Model12V2000Gx6 series
CategoryEngine
LanguageEnglish

Related product manuals