4.4 Product data 12V/16V2000Gx6S, 3G, continuous operation,
time-limited, ICXN, optimized fuel consumption
Legend
DL Reference value: Continuous power. Continuous driving power under standard conditions
BL Reference value: Fuel stop power. Maximum engine power. In some applications, continuous power
not possible (adjustment reserve)
A Design value. Value is required for configuration of an external system (plant)
R Guideline value. Typical average value for information, only partially suitable for design purposes
L Limit value. Value that must not be undershot (lower limit, min. value) or exceeded (upper limit, max.
value); not suitable for configuration
N Value not yet defined. Value has not yet been, or will not be, named
- Not applicable. Module not relevant to this product type
X Applicable. Module relevant to this product type
> Actual value must be greater than the specified value.
< Actual value must be lower than specified value.
* Value not sufficiently guaranteed (tolerance +/- 10%).
** Value not sufficiently guaranteed (tolerance +/- 5%).
ID Product type Application Speed Nominal pow-
er
1 12V2000G26S Power generation
3G continuous opera-
tion, time-limited,
ICXN
1800 rpm
60 Hz
810 kW
1086 bhp
Ref. 25 °C/55 °C; Wa-
ter charge-air cooling
(external)
Optimized fuel con-
sumption
2 16V2000G26S Power generation
3G continuous opera-
tion, time-limited,
ICXN
1800 rpm
60 Hz
998 kW
1338 bhp
Ref. 25 °C/55 °C; Wa-
ter charge-air cooling
(external)
Optimized fuel con-
sumption
Reference conditions
ID 1 2
Intake air temperature °C 25 25
Charge air coolant temperature °C 55 55
Barometric pressure mbar 1000 1000
Site altitude above sea level m 100 100
Performance data
ID 1 2
Rated engine speed A rpm 1800 1800
Continuous power ISO 3046 (10% overload possible) (power
range DIN 6280, ISO 8528)
A kW 810 998
Site conditions (for max. power)
ID 1 2
Intake depression (new filter) A mbar 15 15
Intake depression, max. L mbar 40 40
MS15054/03E 2018-07 | Technical Data | 37
TIM-ID: 0000065013 - 004