4.3 Putting the engine into operation after scheduled out-of-
service period
Preconditions
☑Engine is stopped and starting disabled.
Putting into operation
Item Task
Lube oil system Check oil level (→ Page 187).
Cooling system Check coolant level (→ Page 200).
Cooling system Preheat coolant with preheating unit.
Fuel prefilter Drain (→ Page 176).
Battery-charging generator
drive
Check condition of drive belt (→ Page 208).
Engine control system Switch ON.
Press READY FOR OPERATION button (→ Page 105).
LOP Press LAMP TEST button (→ Page 105).
108 | Operation | MW15406/17E 2014-05
TIM-ID: 0000002684 - 003