4.8 Coupling – Disengaging from LOP
Preconditions
LOCAL OPERATION illuminated pushbutton lights up brightly (local operating mode is active).
Engine speed in disengagement window.
Disengaging coupling without reversing gearbox (CPP, WJ, VS)
Item Measure
LOP Press COUPLING OUT illuminated pushbutton (→ Page 105).
COUPLING OUT button flashes.
Coupling is disengaged.
After receiving the feedback signal from coupling, the COUPLING OUT
button is illuminated brightly.
Disengaging coupling with reversing gearbox (FPP, WJ)
Item Measure
LOP Press COUPLING NEUTRAL illuminated pushbutton (→ Page 105).
COUPLING NEUTRAL button flashes.
Gearbox is disengaged (neutral position).
After receiving the feedback signal from coupling, the COUPLING NEU-
TRAL button is illuminated brightly.