7.19 Battery-Charging Generator
7.19.1 Battery-charging generator drive – Drive belt check and adjustment
Preconditions
☑Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use Part No. Qty.
Assembly device
F6559691 1
Preparatory steps
1. Remove limit switch (4).
2. Remove indicator (1).
3. Remove screws (3) of protective cover (2).
4. Remove protective cover.
5. Check drive belt condition (→ Page 208).
Belt drive – Checking distance
1. Measure distance (A) with assembly de-
vice.
2. If measured value of distance (A) is not
within the tolerance of 98 mm ± 1.5 mm,
readjust belt tension.
MW15406/17E 2014-05 | Task Description | 209
TIM-ID: 0000007388 - 004