4.10 Stopping the engine from LOP (without Blue Line automation
system)
Preconditions
☑Engine is running in Local mode.
NOTICE
Stopping the engine when it is running at full load causes extreme stress to the engine.
Risk of overheating, damage to components!
• Before shutting down, disengage gear and run the engine at idle speed for at least 10 minutes
until engine temperatures have dropped and constant values are displayed.
Stopping the engine from LOP
Item Measure
LOP Disengage gearbox (→ Page 105).
LOP Operate engine at idle speed (→ Page 105).
Temperature indications Wait until engine temperatures do not fall any further.
LOP Press illuminated pushbutton STOP (→ Page 105).
•
STOP pushbutton is illuminated;
•
Engine at a standstill.
MW15406/17E 2014-05 | Operation | 115
TIM-ID: 0000002299 - 004