6 Troubleshooting
6.1 LOP fault messages
AL RCS Speed Demand Defect
Cause Corrective action
No speed demand signal. 1. Check remote control system.
2. Check LOP visually (→ Page 223).
3. Perform LOP test procedures (→ Page 225).
4. Check ECU plug-in connections (→ Page 218).
5. Check engine wiring (→ Page 214).
AL Battery Charger Failure
Cause Corrective action
Battery not being charged. 1. Check power circuit breakers and fuses.
2. Check transistorized regulator.
3. Check drive belt (→ Page 209).
AL Press. Monitoring Fail (EMU)
Cause Corrective action
EMU pressure monitoring
failure.
u Contact Service.
• Have EMU replaced.
AL ECU Defective
Cause Corrective action
ECU 4 is defective. 1. Check LOP visually (→ Page 223).
2. Perform LOP test procedures (→ Page 225).
3. Check ECU plug-in connections (→ Page 218).
4. Check engine wiring (→ Page 214).
5. Contact Service.
• have ECU checked and replaced, if required.
AL Output Stage Bank 1 Fault
Cause Corrective action
Fault message of power output
stage, cylinder bank A
1. Check LOP visually (→ Page 223).
2. Perform LOP test procedures (→ Page 225).
3. Check ECU plug-in connections (→ Page 218).
4. Check engine wiring (→ Page 214).
5. Contact Service.
• have ECU checked and replaced, if required.
MW15406/17E 2014-05 | Troubleshooting | 121