3.3 8V 2000 M60 engine data: Separate heat exchanger,
reference condition: 25 °C intake air temperature
Explanation:
DL Ref. value: Continuous power (CP)
BL Ref. value: Fuel stop power (FSP)
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
REFERENCE CONDITIONS
Engine model 8V
2000 M60
Application group 1A
Intake air temperature °C 25
Raw water inlet temperature °C 25
Barometric pressure mbar 1000
Site altitude above sea level m 100
POWER-RELATED DATA (power ratings are net brake power to ISO 3046)
Number of cylinders 8
Engine rated speed A rpm 1800
Fuel stop power ISO 3046 A kW 400
GENERAL CONDITIONS (for maximum power)
Number of cylinders 8
Intake air depression (new filter) A mbar 15
Intake air depression, max. L mbar 50
MODEL-RELATED DATA (basic design)
Number of cylinders 8
Cylinder configuration: V angle degree 90
Bore mm 130
Stroke mm 150
Cylinder displacement liter 1.99
Total displacement liter 15.92
Number of inlet valves, per cylinder 2
Number of exhaust valves, per cylinder 2
MW15406/17E 2014-05 | Technical Data | 45