HI P-Oil Filter Fifference
Cause Corrective action
Oil pressure difference between
oil pressures before and after
filter too high.
u Replace engine oil filter (→ Page 190).
MG Disengagement Fault
Cause Corrective action
RCS message. u Contact Service.
• Have GCU solenoid checked and replaced, if required.
• Have GCU wiring checked and replaced, if required .
MG Eng Speed High/Low (Clutch)
Cause Corrective action
RCS message. u Speed reduction
MG Engagement Fault
Cause Corrective action
RCS message. u Contact Service.
• Have GCU solenoid checked and replaced, if required.
• Have GCU wiring checked and replaced, if required .
MG Check Start Interlocks
Cause Corrective action
Start conditions are not
fulfiulled.
u Check start conditions and fulfill if necessary.
RL 211+A001-A001
Cause Corrective action
DIS not detected on redundant
bus
1. Check LOP visually (→ Page 223).
2. Perform LOP test procedures (→ Page 225).
3. Contact Service.
• Have DIS checked and replaced, if required.
RL 211+A001-A010
Cause Corrective action
LCU of LOP 1 (PIM No. 21.X
+A001-A010) not detected on
redundant CAN bus.
1. Check LOP visually (→ Page 223).
2. Perform LOP test procedures (→ Page 225).
3. Contact Service.
• Have MPU 23 of PIM No. 21.X+A001-A010 checked and
replaced, if required.
MW15406/17E 2014-05 | Troubleshooting | 125
TIM-ID: 0000042361 - 001