RAW WATER CIRCUIT (open circuit)
Number of cylinders 8
Raw water pump: inlet pressure, min. L bar -0.5
Raw water pump: inlet pressure, max. L bar +0.5
Pressure loss in the external raw water system, max. permissible L bar 0.7
LUBE OIL SYSTEM
Number of cylinders 8
Lube oil operating temperature before engine, from R °C 75
Lube oil operating temperature before engine, to R °C 80
Lube oil operating pressure before engine, from R bar 5.6
Lube oil operating pressure before engine, to R bar 6.1
Lube oil operating pressure, low idle (meas. point: before engine) R bar 2.0
FUEL SYSTEM
Number of cylinders 8
Fuel pressure at supply connection to engine (when engine is starting), min. L bar -0.3
Fuel pressure at supply connection to engine (when engine is running), min. L bar -0.3
Fuel pressure at supply connection to engine (when engine is starting), max. L bar +0.5
Fuel supply flow, max. R liter/min 1.4
GENERAL OPERATING DATA
Number of cylinders 8
Firing speed, from R rpm 100
Firing speed, to R rpm 120
STARTING (electric)
Number of cylinders 8
Rated starter voltage (standard design) R V= 24
STARTING (pneumatic starter)
Number of cylinders 8
Starting air pressure before starter motor, min. R bar 18
Starting air pressure before starter motor, max. R bar 30
INCLINATIONS, STANDARD OIL SYSTEM (relative to: waterline)
Number of cylinders 8
Longitudinal inclination continuous max. drive side down (Design: max. operat-
ing inclinations)
L degree 15
Longitudinal inclination temporary max. drive side down (Design: max. operat-
ing inclinations)
L degree 22.5
Longitudinal inclination continuous max. drive side up (Design: max. operating
inclinations)
L degree 0
40 | Technical Data | MW15406/17E 2014-05
TIM-ID: 0000002883 - 001