RX1575 SERIES TRENCH ROLLER • OPERATION MANUAL S/N 3069933~ — REV. #0 (11/29/23) — PAGE 63
UNIT OVERTURNING
70 RAMMAX 1575
555133
555134
hours
557086
6
2.7 Machine control and use
2.7.13 Roller overturning
If the machine is overturned, the motor will automatically
switch o.
Raise the machine back onto the drums as quickly as pos-
sible using a crane.
Turn the key to the 0 position, turn it o.
The machine overturning is indicated by the machine over-
turning indicator lamp (6) on the machine display.
Engine start is blocked and a process is required to unblock.
Contact your dealer for unblocking.
Under no circumstances should you try to restart the en-
gine right away.
It can cause serious engine damage.
If the machine overturns, contact your dealer.
Operating uids pose a risk to the environment!
Do not allow any liquids into drains, soil or the surround-
ing environment.
Immediately prevent the spread of any liquids leaking
out, e.g. oil, diesel, antifreeze, battery acid.
2.7.12. 2D ROPS function
The main purpose of the 2D ROPS function is to prevent the
machine from overturning.
If the machine reaches an inclination of 15° (27%), the vibra-
tion switches o.
An acoustic signal sounds.
The beacon starts ashing.