PAGE 54 — RX1575 SERIES TRENCH ROLLER • OPERATION MANUAL S/N 3069933~ — REV. #0 (11/29/23)
DRIVING AND BRAKING
2.7.4 Driving and braking
Overview of functions
Remote control and cable Remote control
Stop zone 0,5 m 0,5 m
Protected zone (1) approx. 0–2 m approx. 0–2 m
Safe zone (2A) 2-5 m approx. 2-20 m
Maximum range approx. 5 m approx. 20 m
Functions Forward / reverse
Left / right steering
Working / transport speed
Vibration – high / low amplitude
The distances of the individual zones are stated from the sensors (10) located on the bonnet, not from the machine
frame!
It is forbidden to extend the remote control cable to a distance longer than 5metres.
Extending the cable to more than 5m may pull the remote control out of the operator’s hand, or the cable or remote
control may be damaged.
After any function requiring machine movement (forward and
reverse, left and right steering, vibration), the engine speed is
automatically increased to the working speed. If no function is
activated for 15 seconds, the engine speed is automatically re-
duced to idle speed.
Driving forwards / backwards
• Move the switch:
- toward the front: The machine moves forward,
- toward the rear: The machine moves backward.
Steering left / right
• Move the switch:
- toward the left: the compactor turns left,
- toward the right: the compactor turns right.