3.6.4 Hydraulic tank oil level check
Always check the hydraulic oil level at operating tempera-
ture with the engine running.
Place the machine on level ground.
Let the machine continue to idle.
Check the oil level in the inspection window.
The ideal oil level is when the gauge is half-full.
Topping up hydraulic oil
Remove the screw lid (1) on the ller neck.
Rell hydraulic oil if necessary.
Reinstall the screw lid (1).
Important: Always grease the O-ring before screwing it
in place.
Check oil when it is cooled down.
Rell the identical type of oil to chapter 3.2.4.
Avoid leakage of oil to the soil.