48
PGN
65307(0xFF1B)
Source Address
224(0xE0)
PDU Format
255(0xFF)
PDU Specic
27(0x1B)
Built Message
(0x18FF1BE0)
J1939FrequencyStatus
Name Data Type Byte Bits Description
Hertz_CountInput7A Word 1 Low Byte
Input7A,Hertzisusedwhentheinputisconguredasafrequencyinput,
Countisusedwhentheinputisconguredasahighspeedcounter
2 HighByte
DutyCycle_SPInput7A Word 3 Low Byte
Input7A,Duty Cycleisusedwhentheinputisconguredasafrequencyinput,
Set Pointisusedwhentheinputisconguredasahighspeedcounter
4 HighByte
Hertz_CountInput8A Word 5 Low Byte
Input8A,Hertzisusedwhentheinputisconguredasafrequencyinput,
Countisusedwhentheinputisconguredasahighspeedcounter
6 HighByte
DutyCycle_SPInput8A Word 7 Low Byte
Input8A,Duty Cycleisusedwhentheinputisconguredasafrequencyinput,
Set Pointisusedwhentheinputisconguredasahighspeedcounter
8 HighByte
****In encoder mode, bytes 1&2 are the low word and bytes 3&4 are the high word*****
Transmit rate
50 ms
Msg timeout
200 ms
Priority
6
DP
0