Selection of modem connection Disabled Enabled/Disabled
414 Communication format setting Character bit:
8 bits,
Parity check:
“with, odd”
Stop bit: 1 bit
Enter the settings for the various items.
Character bit: 7bits/8bits
Parity chk: none/with odd/with even
Stop bit: 1bit/2bits
The following setting is valid only when the
communication mode specified by system
register 412 has been set to “General com-
munication”.
End code (Terminator): CR/CR+LF/None
Start code (Header): STX not exist/STX
exist
415 Communication speed (Baud rate)
setting
9600 bps 2400 bps
4800 bps
9600 bps
19200 bps
38400 bps
57600 bps
115200 bps
418 Starting address for received buffer of
general (serial data) communication
mode
2048 0 to 32764
419 Buffer capacity setting for data re-
ceivedofgeneral (serialdata)commu-
nication mode
2048 0 to 2048
Note
The communication format when using the PLC link is fixed at
the following settings:
the data length is 8 bits, odd parity, stop bit is 1.
The communication speed (baud rate) is fixed at 115,200 bps.