NCR SelfServ 34 ATM Installation Guide
B006-6590-C000 23
10. Make sure that all of the collar parts are as tight as possible and that there are no
visible gaps between the collar and the facia. Secure with two M4 x 6 machine screws
removed earlier.
11. Refit the lower collar moulding removed earlier. Locate the interlocking tabs on the
lower collar moulding with the vertical sides on the collar. Secure underneath at each
corner using two M4 x 10 screws.
12. Pull the ATM back against the building wall to ensure a tight fit.
13. Remove the ATM from its moving device.
14. Select an appropriate silicone sealant for the wall type and colour. Prior to applying
the sealant, ensure the joining surfaces are clean, dry and free of grime. Apply the
sealant around all the edges, wall and joins, ensuring there is a waterproof seal
between the ATM and the wall.