NCR SelfServ 34 ATM Installation Guide
32 B006-6590-C000
2. Open the security enclosure.
3. Locate the four holes in the base of the security enclosure. Position washers, insert the
four bolts through the holes and secure the ATM to the floor.
4. Close and lock the security enclosure.
5. Close and lock the exterior of the ATM.
Connecting the Cables
The cables used to make connections to the ATM must conform to the cable specifications
and details of preparation provided in the publication, NCR SelfServ 32, 34, 38 Site
Preparation Requirements (B006-6670).
Note: Because there is a limited side clearance when the ATM is being installed within a
minimum footprint clearance area, cable connections must be carried out before the unit is
moved into its final location.
Cables to be connected to the ATM fall into two categories:
● Power cable - does not require additional grounding
● All other cables require additional grounding by means of a “P” clamp which can be
found in the accessories bag. Refer to the publication, NCR SelfServ 32, 34, 38 Site
Preparation Requirements (B006-6670) for the list of cables which require grounding.
CAUTION
Cables must be grounded to make sure that the ATM meets EMC
requirements.