Section 3: Features
Product Description 171
3
Station Park
Please refer to Park (page 156) for information on this feature.
Station Relocation
Please refer to Maintenance (page 134) (Extension Data Swap) for information on this feature.
T1 Trunking (with ANI/DNIS Compatibility)
Description
The T1/PRI Interface PCB gives the system T1 trunking capability. This PCB uses a single univer-
sal slot and provides up to 24 trunk circuits. In additional to providing digital-quality trunking, the
T1/PRI Interface PCB allows you to have maximum trunking capability with fewer PCBs. This in
turn makes more universal slots available for other functions.
You can program each T1/PRI PCB for any combination of the following trunks:
CO loop start
CO ground start
Direct Inward Dialing
Tie lines
1
The T1/PRI Interface PCB uses the Þrst block of 24 consecutive trunks. For example, if you have
an 8COIU PCB installed for trunks 1-8, the T1/PRI Interface PCB will automatically use trunks 9-
32. If you have 8COIU PCBs installed for trunks 1-8 and 17-24, the T1/PRI PCB will use trunks
25-48. The T1/PRI Interface cannot use trunks 9-16 (even if available) since they are not part of a
consecutive block of 24 trunks. Each T1/PRI PCB requires that 24 consecutive ports be available in
the system even if not all the ports will be used otherwise the PCB will not function.
Aspire S Aspire M/L/XL
Not Available. Available
ANI/DNIS Compatibility is available.
This feature requires the Basic NTCPU (P/N 0891002)
with the PAL upgrade or the Enhanced NTCPU (P/N
0891038) unless using software 4.0E or higher.