4-44 Configuring Your Server
Default settings and their explanation
Item Default Description Change
Battery Backup Present
None
Displays Properties.
When battery is installed: Present
When battery is not installed: None
Set Factory Defaults No
Yes
Restores factory defaults. Permitted
Cluster Mode Disabled Prohibited
Rebuild Rate 30 Recommended value: 30 Permitted
Patrol Read Rate 30 Recommended value: 30 Permitted
BGI Rate 30 Recommended value: 30 Permitted
CC Rate 30 Recommended value: 30 Permitted
Reconstruction Rate 30 Recommended value: 30 Permitted
Adapter BIOS Enabled
Disabled
Prohibited
Coercion Mode None
128MB-way
1GB-way
Prohibited
PDF Interval 300 Prohibited
Alarm Control Disabled
Enabled
Silence
Disabled: Does not issue an alarm. Prohibited
*2
Cache Flush
Interval
4 Prohibited
Spinup Drive Count 2 Prohibited
*1
Spinup Delay 6 Prohibited
*1
StopOnError Disabled
Enabled
Prohibited
*1 After performing Set Factory Defaults, change values of "Spinup Drive Count" and "Spinup
Delay" as shown in the table above, if they are not.
*2 Error notification by beep sound is not issued even if Alarm Control is set to Enabled.