4-6 Configuring Your Server
Security
To set BIOS passwords
Select [Security] – [Set Supervisor Password] and enter a password.
Set the Supervisor password first, and then the User password.
To enable/disable the POWER switch
Select [Security] – [Power Switch Inhibit] – [Disabled].
Select [Security] – [Power Switch Inhibit] – [Enabled].
To set this item, the Supervisor and User passwords must be set.
IMPORTANT:
Even if [Power Switch Inhibit] is set to [Enabled], the
forced shutdown procedure is still available.
External Devices
To set up external devices
Select [Advanced] – [Peripheral Configuration] and set up each device.
Internal Devices
To set up internal PCI devices of the CPU blade
Select [Advanced] – [PCI Configuration] and set up each device.
To clear the hardware configuration data (after installing/removing internal devices)
Select [Advanced] – [Reset Configuration Data] – [Yes].
Saving the Configuration Data
To save the BIOS configuration data
Select [Exit] – [Exit Saving Changes] or [Save Changes].
To discard changes to the BIOS configuration data
Select [Exit] – [Exit Discarding Changes] or [Discard Changes].
To load the default BIOS configuration data (may differ from factory-set values)
Select [Exit] – [Load Setup Defaults].
To save the current settings as a user-defined configuration
Select [Exit] – [Save Custom Defaults].
To load the user-defined configuration data
Select [Exit] – [Load Custom Defaults].