Database Transfer Utility
5-8 Section 5: Maintenance Options and SMDR DS1000 Hardware Manual
If the destination system does not recover from the reset, the transfer was incomplete and the data-
base has become corrupted. You’ll need to shut the system down, pull the battery from the CPU (for
about 5 minutes) and then restart the system. The default database will automatically be reinstalled.
9. When the Database Transfer completes, set the MODE switch on the source system back to RUN and
press the red reset button.
10. To repeat the Database Transfer procedure, you must
start over again from step 1.
Table below explains the Power LED ash rates that occur during Database Transfer.
Power LED Flash Rates During Database Transfer
Source System
Destination System
While Database Transfer is in
progress:
Flashes briey red, then ashes
green.
Flashes briey green, the alter-
nately ashes red and green.
When Database Transfer
completes:
Flashes red/green. Flashes slowly green.

Table of Contents