Technical Specifications A-5
Tape Drive
Table A-3 lists the technical specifications for the optional tape drive in the
optional PCIX Unit.
Table A-3. Optional Tape Drive Technical Specifications
Item Specification
Corresponding standard and
memory capacity
DDS4 150m 40GB
DDS3 125m 24GB
DDS2 120m 8GB
DDS1 90m 4GB (Supports read-only)
Average Transmission Rate Non-compression: 3 MB/s
Compression (2:1): 6 MB/s
Interface SCSI-2
Memory Buffer 8 MB
MTBF 400,000H
Life Time Tape Access 6000H
Dimensions Width: 4 inches (101.6 mm)
Height: 1.6 inches (41.3 mm)
Depth: 5.9 inches (150 mm)
Environment
Operating
Non-operating
Temperature: 41° to 104°F (5° to 40°C)
Relative Humidity: 20% to 80% (non-condensing)
Temperature: -40° to 158°F (-40° to 70°C)
Relative Humidity: 5% to 95% (non-condensing)