Service Processor 3-27
EN (Environmental Information)
NML MNT m b u
X X X
This command lists the states of the system’s detected temperature and fan errors, etc.
The components in the DC POWER OFF state are not supervised.
Table 3-30. EN Screen
Screen Image Reference
iSPyz:---> en<ENTER>
---- Power Bay Units ---------------------------------------------------------- 19:20:57,01/31/2002 ----
state DPS0 DPS1 DPS2 DPS3 DPS4 DPS5
* MAIN PBAY00 ON --- --- ALARM ---
* PBAY01 ON --- --- NORESP ---
PBAY02 ON --- --- ---
IOX PBAY10 OFF --- --- --- ---
PBAY11 OFF --- --- --- ---
-----------------------------------------------------------------------------------------------------------------------
A
---- MAIN cabinet FANs ------------------------------------------------------ 19:20:57,01/31/2002 ----
0 1 2
*Front upper low ALARM low
Front lower --- --- ---
*Rear upper HIGH HIGH ALARM
Rear lower --- --- ---
-----------------------------------------------------------------------------------------------------------------------
B
Next page? (n[ext]/e[xit]/CR=next) : <ENTER>
C
---- CELL/XBC board DD-con/Temp alarm ----------------------------- 19:20:57,01/31/2002 ----
state DD-con Temp
CELL0 ON
* CELL1 OFF ALARM
* CELL2 NORESP
* CELL3 OFF ALARM
CELL4 --- --- ---
CELL5 --- --- ---
CELL6 --- --- ---
CELL7 --- --- ---
* XBC0 OFF ALARM
* XBC1 NORESP
XBC2 ON
XBC3 ON
-----------------------------------------------------------------------------------------------------------------------
D
Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER>
---- PCIX-BOX DD-con/Temp/FAN alarm ------------------------- 19:20:57,01/31/2002 ----
state DD-con Temp FAN Local/Remote
PCIX0(F) ON Remote
* PCIX1(F) OFF ALARM ALARM Remote
* PCIX2(F) ON --- ALARM Local
* PCIX3(F) OFF --- ALARM Remote
PCIX4(-) --- --- --- --- ---
* PCIX5(F) NORESP
PCIX6(F) ON Remote
PCIX7(F) OFF Remote
----------------------------------------------------------------------------------------------------------------------
E