Service Processor 3-39
Table 3-35 HC Subcommands (cont’d)
cmd arg1 arg2 arg3 arg4 Description
procxy
- - - Adds a processor.
“x” is the physical CELL Board number (0-7).
“y” is the processor installation location on the
CELL Board (0-3).
mmcx1
- - - Adds a MMC (and ROW) on the Memory
Daughter Board. The capacity of the DIMM is
automatically read at memory initialization.
“x” is the physical number of the CELL Board
(0 or 7).
add
(cont’d)
pcixx
f|h [bio] - Adds a PCIX Unit.
“x” is the DGI/12C port number of the iSP side
(0-7).
“f|h” specifies the type of PCIX Unit (f[full]/h[alf].
If the Basic I/O Board is attached, specify “bio”
as the third argument.
- - - - Used to delete a component from the iSP
management. If you do not delete it from the
iSP management, the component which has
been physically removed will still be managed
as “INVISIBLE”.
You cannot delete any components in the DC
ON state (except CLK Board and Distributed
Power Supply Module).
Displays Help for “delete” when the argument is
omitted or an error is made.
delete
<arg1>
- - -
<arg1> is the same as described in “add”.
- - - - Used to enable a component managed as
”DISABLE”.
Displays Help for ”enable” when the argument is
omitted or an error is made.
pbayxy
- - - Enables the Power Bay Unit.
“x” is the cabinet number.
0: Main Cabinet
1: I/O Expansion Cabinet
“y” is the ID number within the cabinet.
0-2 in the Main Cabinet
0-1 in the I/O Expansion Cabinet
enable
clkx
- - - Enables the CLK Board.
“x” is the physical CLK Board number (0 or 1).