EasyManua.ls Logo

NEC Express5800 140He - Page 106

NEC Express5800 140He
398 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-32
Menu Description
+Adapter Set disk array controller
+Clear Configuration Clear configuration
*1 FlexRAID PowerFail Set whether to restart after rebuilding
*2 Fast Initialization Set high-speed initialization
*3 Disk Spin up Timing Set hard disk spin-up
*4 Cache Flush Timing Set cache flush timing
*5 Rebuild Rate Set rebuild rate
*6 Alarm Control Set alarm sound (ON / OFF)
+Other Adapter Information Board information display (FW version, etc.)
FW Supports
FW type
FW Ver
FW version
BIOS Ver
BIOS version
DRAM
Memory capacity
Adapter Type
Board series NO.
+Factory Default Set default value
*7 Disable (Enable) BIOS Set BIOS Enable / Disable
+Battery Information Battery information
Backup Module
Existence of battery module
Battery Pack
Existence of battery pack
Temperature
Battery temperature
Voltage
Battery voltage
Fast Charging
Set fast charging status
No of Cycles
The number charge cycle
+Reset Battery Charge Counter Clear battery charge counter
+Other Adapter Options Adapter detailed options
*8 Emulation Set control mode
*9 Auto Rebuild Set auto rebuilding Enable / Disable
Initiator ID
Indicate Initiator ID No.
*10 Cluster Mode Set cluster mode
*11 Multiple PCI Delayed Trans Set PCI bus bridge
*12 Force Boot Forced setting of configuration information(HDD)
*13 Coercion Algorithm Setting parameter for maximum hard disk capacity
Abort BI & CC Activities Abort Background initialize or Check Consistency
*14 CC Restoration Select CC Restoration mode
*15 Temporary Offline RAID Set Temporary offline Enable / Disable
+Logical Drive Logical drive operation
+Logical Drives Select logical drive
+Initialize Initialize logical drive
+Check Consistency Check logical drive redundancy
+View/Update Parameters Display logical drive information
RAID
Display RAID level
SIZE
Display logical drive capacity
Stripe SIZE
Display stripe size
+ Write Policy
Set write mode
+ Read Policy
Set read mode
+ Cache Policy
Set cache mode
+ FlexRAID Virtual Sizing
Set virtual sizing Enable / Disable *Do not set to Enable
#Stripes
Display stripe size
State
Display logical drive status
+Physical Drive Physical drive menu
+Physical Drive Selection Menu Physical drive operation
+Rebuild Perform rebuilding
+Format Perform low level format
*Do not use
+Make Online Set the disk online

Table of Contents

Related product manuals