Loading...
4-33
Menu Description
+Fail Drive Set the disk offline
+Make HotSpare Set as stand-by disk for auto rebuilding
+View Drive Information Display hard disk information
Device Type
Hard disk type
Capacity
Hard disk capacity
Vender ID
Hard disk vender name
Product ID
Hard disk model
Revision
Hard disk revision
SCSI Standard
SCSI standard
Media Errors
The number of media errors
Other Errors
The number of other errors
*16 Synchronous Negotiation SCSI synchronous negotiation
*17 SCSI Command Q Tagging Set SCSI command Q Tag
+Channel Set channel
+Channels Chose SCSI channel
*18 Termination State Set termination state
*19 Enable Auto Termination Set auto termination state
*20 SCSI Transfer rate Set transfer rate
+Format Perform low level format
*Do not use
+Rebuild Perform rebuilding
+Check Consistency Perform logical drive redundancy check
+Select Adapter Select disk array controller
* This menu item does not appear if no disk array controller is installed
in the computer.
Setting values
No. Setting parameter Factory setting Setting change
*1 FlexRAID PowerFail ENABLED Do not change
*2 Fast Initialization ON Variable setting
*3 Disk Spin-up Timing 2 disks every 6 secs Do not change
*4 Cache Flush Timing Every 4 Seconds Do not change
*5 Rebuild Rate 30% Variable setting
*6 Alarm Control Disable Alarm Do not change
*7 Disable(Enable) BIOS Enable (Display: Disable BIOS) Do not change
*8 Emulation MASS STORAGE Do not change
*9 Auto Rebuild ENABLED Do not change
*10 Cluster Mode DISABLED Do not change
*11 Multiple PCI Delayed Trans ENABLED Do not change
*12 Force Boot ON Do not change
*13 Coercion Algorithm NONE Do not change
*14 CC Restoration ENABLED Variable setting
*15 Temporary Offline RAID ENABLED Do not change
*16 Synchronous Negotiation Enabled Do not change
*17 SCSI Command Q Tagging Enhanced QTAG Scheduling Do not change
*18 Termination State Enabled Do not change
*19 Enable Auto Termination No Do not change
*20 SCSI Transfer rate 320M Do not change
Changing factory settings
The settings for the following items can be changed. Follow each explanation:
*2 Fast Initialization
A setting of "On" is recommended.
This initializes the top area of the disk only.
*5 Rebuild Rate A setting of "30%" is recommended.
*14 CC Restoration Factory setting is "ENABLED".

Table of Contents