CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 93 – NWA-008847-001 Rev.3.0
a6ch1001.fm
If the fault that occurred when D
term
IPs and IP-CSs login to the system or the IP-PAD card is in on-
line status is the self-control reset of terminal, the fault logs can be registered as the fault information
(assigned by CMEA Y=2>49). In this case, D
term
IP is registered per terminal, IP-CS is registered per
CS, and IP-PAD is registered per card. “FAULT MESSAGE” Page 10
To collect multiple fault logs, at least a four-second interval is required for collecting each log. Also,
you can reserve up to eight logs collection (the ninth or more reserved log is invalid).
Since the recorded reset time of fault logs depends on the terminal clock to collect logs, it may differ