CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 52 – NWA-008847-001 Rev.3.0
a6ch1001.fm
Operating Procedure
Refer to the IMX or IPX RMAT Operation Manual.
DESCRIPTION DATA
Assign the outgoing access code and called
party number to Memory Slot number allo-
cated by CM71.
•Y=0
(1) 000-299: Memory Slot No.
(2) Outgoing Access Code (Maximum 4
digits) + + Called Party No. (Maxi-
mum 26 digits)
Assign which kind of fault information is
stored into the fault information memory,
and which kind of alarm is indicated.
•Y=2
(1) See “FAULT MESSAGE” of
(2) CHAPTER 1. Page 10
Specify the alarm kind sent automatically
to the RMAT.
•Y=3
(1) 00 : MJ alarm
01 : MN alarm
02 : - - alarm
(2) 0 : Send
1 : Not sent
Assign the office number sent to the
RMAT.
•Y= 4
(1) 00 : Office number sent to RMAT
(2) 00-999: Office No.00-999
Specify the destination of fault information
as RMAT.
•Y=4
(1) 01 : Destination of fault information
(2) 3 : IMX MAT or Centralized MAT
and RMAT
7: RMAT
CM72
A
CMEA
END
,