CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 46 – NWA-008847-001 Rev.3.0
a6ch1001.fm
Programming Procedure
DESCRIPTION DATA
Assign the date and time setting for
periodic maintenance.
(1)
(2)
Y=2
00-07: Periodic maintenance
YYYY MM DD HH
YYYY: 2000-2099 (Year)
MM : 01-12 (Month)
DD : 01-31 (Date)
HH : 00-23 (Hour)
Assign the check item for periodic main-
tenance.
(1)
(2)
Y=3
00-07: Periodic maintenance
0: Battery check
1-7 : Check item No.1-No.7
Specify the D
term
for alarm display, if
required.
(1)
(2)
Y=16
01: D
term
No.1
02: D
term
No.2
X-XXXXXXXX: My line number of D
term
Assign the alarm indication key to D
term
function key, if required.
(1)
(2)
Y=00
My Line No. + +Key No.
F5020: Alarm display
Set the alarm kind for periodic mainte-
nance.
(1)
(2)
Y=2
16
1: MN alarm
2: MJ alarm
CM43
START
END
CM51