CHAPTER 3 MAINTENANCE OPERATION
– 240 – NWA-008847-001 Rev.3.0
a6ch3001.fm
SAVING D
term
IP ID REGISTRATION DATA TO YOUR PC
The following procedure explains how to save (backup) ID registration data for D
term
IP to your PC.
For hardware connection of MAT and PBX and for MATWorX software installation, refer to the MAT-
WorX Installation Guide.
STEP1: After starting up the MATWorX, select PBX Connect from the taskbar. And follow Con-
figuration Wizard dialog to make the connection to the PBX.
STEP2: Select System Save/Load/Verify from the taskbar.
The Save/Load/Verify dialog is displayed.
Select the MP card and select the [Other] from the pulldown menu of the Area name. Then, in-
put 80 in Area number text box.
NOTE 1: ID registration data for D
term
IP cannot be saved by the basic area name “All office data for
MP (Basic+Option)” on the Save/Load/Verify dialog.
NOTE 2: To load the registered data from your PC, reset the MP card after loading operation.
It takes 5 minutes to start up the D
term
IP after MP card is reset.
Click this button and select [Other]
Input 80
Select MP card
SAVING D
term
IP ID REGISTRATION DATA TO YOUR PC