CHAPTER 2 TROUBLESHOOTING
– 225 – NWA-008847-001 Rev.3.0
a6ch2001.fm
D
term
IP Fault
This troubleshooting procedure covers faults with D
term
IP function only. For other faults, see “Station Line
Fault”. Page 209
All Keys on the D
term
IP are ineffec-
tive.
(1) Wiring on the LAN
(2) IP-PAD card is properly mounted.
(3) System Data Programming for the
D
term
IP station and IP-PAD: CM0A,
CM0B, CM05, CM10/CM14, CM11,
CM12, CM13, CM90, CM93
(4) D
term
IP setup is properly completed by
D
term
IP menu.
(5) “RUN” Lamp on the MP card is flash-
ing.
(1) D
term
IP
(2) IP-PAD card
(3) MP card
Speech Path Trouble:
No Connection/One Way Connec-
tion
(1) D
term
IP
(2) IP-PAD card
Hands Free Operation is not
available.
(1) “MIC” Lamp is on.
(2) Adjust speaker volume.
(3) Built-in Hands Free Unit is properly
mounted.
(1) Hands Free Unit within D
term
IP
(2) D
term
IP
START
A
CHECK
REPLACE
REPLACE
CHECK