CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 97 – NWA-008847-001 Rev.3.0
a6ch1001.fm
Programming Procedure
(1) To execute the fault logs/call logs collection, do the following programming.
[Series 3500 software required]
DESCRIPTION DATA
Provide the call log collection with the PN-
8IPLA (IP-PAD)/PN-8IPTA (SIP).
NOTE: When changing this data for IP-PAD
accommodated in a remote site, exe-
cute the office data copy by CMEC
Y=8 to the remote site.
•
(1)
(2)
Y=76
00-31: LAN Interface No.
0: To provide
1: Not provided
Provide the fault log collection with the PN-
8IPLA (IP-PAD).
•
(1)
(2)
Y=77
00-31: LAN Interface No.
0: Not provided
1: To provide
Assign Service Restriction Class C to the re-
quired stations.
•
(1)
(2)
Y=07
X-XXXXXXXX: D
term
IP Station No.
00-15 : Service Restriction Class C
Allow call log collection in Service Restriction
Class C assigned by CM12 Y=07.
NOTE: When changing this data for termi-
nals accommodated in a remote site,
execute the office data copy by
CMEC Y=8 to the remote site.
•
(1)
(2)
Y=194
00-15: Service Restriction Class C assigned
by CM12 Y=07
0 : Allow
1 : Restricted
Allow fault log collection in Service Restric-
tion Class C assigned by CM12 Y=07.
•
(1)
(2)
Y=195
00-15: Service Restriction Class C assigned
by CM12 Y=07
0 : Restricted
1 : Allow
START
CM0A
CM12
CM15
A
JULY/01/2006
VoIP LOG COLLECTION