CHAPTER 2 TROUBLESHOOTING
– 140 – NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Fault Kind
Continued on next page
FAULT
KIND
NUMBER
FAULT CONTENT FAULT INFORMATION REMEDIAL ACTION
01 System
initialization
Initial Kind 7: Serious failure 5 Replace the MP card.
Initial Kind 8: Serious failure 6 Replace the MP card.
Initial Kind 9: SW3 was changed to 0 No specific action is
required.
Initial Kind A: Serious failure 7 Replace the MP card.
Initial Kind B: Initialize by CAT/MAT No specific action is
required.
04 MP-FP/AP communi-
cation failure
3: XX XX XX XX
Communication Failure Kind
00: Overflow of data sending
buffer to the FP/AP
01: Invalid data received from
FP/AP
Number of communication
failures
FP/AP Number
[Series 3200 R6.1 or before]
C0-C3 : FP No. 00-03
D0-D3: FP No. 16-19
C4-CF : AP No. 04-15
D4-DF: AP No. 20-31
[Series 3200 R6.2]
C0-CF : FP No. 00-15
D0-DF: FP No. 16-31
C4-CF : AP No. 04-15
D4-DF: AP No. 20-31
[Series 3300 or later]
C0-CF : FP No. 00-15
D0-DF: FP No. 16-31
E0-EF : FP No. 32-47
F0-FF : FP No. 48-63
C4-CF : AP No. 04-15
D4-DF: AP No. 20-31
Replace the correspond-
ing FP or AP card indi-
cated in the FP/AP
Number.
1 2 3
1
2
3
FAULT DIAGNOSIS AND TROUBLESHOOTING

Table of Contents