CHAPTER 2 TROUBLESHOOTING
– 147 – NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Fault Kind
Continued on next page
FAULT
KIND
NUMBER
FAULT CONTENT FAULT INFORMATION REMEDIAL ACTION
20 DTI line failure Fault Detail Kind 01: Frame loss
Fault Detail Kind 02: Multi frame loss
Fault Detail Kind 03: AIS error
Fault Detail Kind 04: Remote alarm Replace the DTI card.
Fault Detail Kind 05: Multi remote
alarm
Fault Detail Kind 06: S-bit error Check the DTI cable con-
nection.
Fault Detail Kind 08: CRC error
Fault Detail Kind 09: Slip detected
Fault Detail Kind 0A:Main signal all 1
(for BRT)
Fault Detail Kind 0B:INFO 0
(for BRT)
Fault Detail Kind 0C:INFO 2
(for BRT)
21 DCH/BRT/PRT
D-channel link con-
nection failure
3: XX XX XX XX
D-channel circuit No.
In case of DCH/BRT/PRT
00-07: Channel No. 0-7
Check the status of the
local office line or public
network line.
22 CCH/IPT link con-
nection failure
3: XX
XX XX XX
CCH/IPT No.
00-07: CCH/IPT No. 0-7
Check the status of the
local office line or
remote office line.
24
[Australia
Only]
Number of faulty
trunks was more than
predetermined num-
ber
Search for a line fault
trunk by CMB0 Y=1
or CMF5 Y=0.
Check to see if the
trunk line is faulty.
1
2
FAULT DIAGNOSIS AND TROUBLESHOOTING