EasyManua.ls Logo

NEC NEAX 2000 IPS - Page 208

NEC NEAX 2000 IPS
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 2 TROUBLESHOOTING
– 198 – NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Lamp Status
Continued on next page
CARD NAME
LAMP
STATUS
FAULT
CONTENT
REMEDIAL ACTION
PN-8COTT
(COT)
[For Australia]
LF lamp is on Transmission line
fault
Search for a line fault by CMB0
Y=1 or CMF5 Y=0.
Check to see if the trunk line is
faulty.
PN-2CSIA
(CSI)
[For PCS]
OPE lamp is not
on
D-channel link is
not connected
between CSH and
CSI
Confirm the programming data:
CM06 Y=10.
Confirm if the corresponding CSH
card is removed.
If the fault cannot be cleared,
replace the card.
B00-B12 lamp is
flashing
ZT is not con-
nected to the cor-
responding circuit
No.
Confirm the programming data:
CM06, CM10/CM14, CMAD.
Confirm cable connection and the
power switch of the corresponding
ZT.
Confirm if the corresponding ZT is
in make-busy status.
PN-2CSIA-A
(CSI)
[For PHS]
OPE lamp is not
on
D-channel link is
not connected
between CSH and
CSI
Confirm the programming data:
CM06 Y=10.
Confirm if the corresponding CSH
card is removed.
If the fault cannot be cleared,
replace the card.
B00-B12 lamp is
flashing
CS is not con-
nected to the cor-
responding circuit
No.
Confirm the programming data:
CM06, CM10/CM14, CMAD.
Confirm cable connection and the
power switch of the corresponding
CS.
Confirm if the corresponding CS is
in make-busy status.
1
2
1
2
3
1
2
3
1
2
3
1
2
3
FAULT DIAGNOSIS AND TROUBLESHOOTING

Table of Contents

Other manuals for NEC NEAX 2000 IPS

Related product manuals