EasyManua.ls Logo

NEC NEAX 2000 IPS - Page 28

NEC NEAX 2000 IPS
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 18 – NWA-008847-001 Rev.3.0
a6ch1001.fm
(2) To clear the MJ/MN alarm by external key
DESCRIPTION DATA
Assign the card number for External Key
Interface (PN-DK00) to the desired LEN.
NOTE1: We recommend the setting of card
number for External Key Interface
by CM14, when using Series 3200
R6.2 software or later.
NOTE2: The card number of the External
Key Interface (PN-DK00) must be
assigned to the first LEN (LEVEL
0) and third LEN (LEVEL 2) of
each card slot.
NOTE3: Circuit No. 3 of E963 is used for
built-in External Key Interface of
MP card by setting CM61.
(1)
(2)
000-763: LEN
E900-E963:
Card No. of External Key Interface
(PN-DK00)
For PIM0/1: E900-E915
For PIM2/3: E916-E931
For PIM4/5: E932-E947
For PIM6/7: E948-E963
Assign the card number for External Key
Interface (PN-DK00) to the desired LEN.
[Series 3200 R6.2 software required]
NOTE1: The card number of the External
Key Interface (PN-DK00) must be
assigned to the first LEN (LEVEL
0) and third LEN (LEVEL 2) of
each card slot.
NOTE2: Circuit No. 3 of E963 is used for
built-in External Key Interface of
MP card by setting CM61.
(1)
(2)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
E900-E963:
Card No. of External Key Interface
(PN-DK00)
For FP No.00: E900-E915
For FP No.01: E916-E931
For FP No.02: E932-E947
For FP No.03: E948-E963
Assign the function of MJ/MN alarm
clear key to the external key.
(1)
(2)
Y=30
XX Z
XX : 00-63 : Card No. of PN-DK00
Z : 0-3 : Circuit No.
633 : MP built-in External Key Interface
00: MJ/MN alarm clear key
CM61
CM10
START
END
CM14
FAULT MESSAGE

Table of Contents

Other manuals for NEC NEAX 2000 IPS

Related product manuals