Fault Alarm Date CPU Description
04 MN 02/01/08 13:26 MP MP-FP/AP communication failure
Overflow of data sending buffer to FP/AP. (Count = 10 FP/AP NO. = 04)
Data = (F0 0A 04 FF FF FF FF FF)
04 MN 02/01/08 13:26 MP MP-FP/AP communication failure
Invalid data received from FP/AP. (Count = 96 FP/AP NO. = 07)
Data = (F1 60 07 FF FF FF FF FF)
04 MN 02/01/08 13:26 MP MP-FP/AP communication failure
Invalid data received from FP/AP. (Count = 100 or more FP/AP NO. = 11)
Data = (F1 FF 0B FF FF FF FF FF)
08 MN 02/01/08 13:26 MP FP/AP card down
(FP/AP NO. = 52)
Data = (F4 FF FF FF FF FF FF FF)
09 MJ 02/01/08 13:26 MP Power failure
Power Failure Kind : AC input failure
Data = (00 01 02 FF FF FF FF FF)
09 MJ 02/01/08 13:26 MP Power failure
Power Failure Kind : Fuse break
Data = (01 02 00 FF FF FF FF FF)
09 MJ 02/01/08 13:26 MP Power failure
Power Failure Kind : PWR alarm
Data = (02 00 01 FF FF FF FF FF)
12 MN 02/01/08 13:27 MP CS/ZT fault occurred
Fault kind : Fault notice from CS/ZT (CS/ZT No. = 10)
Data = (00 04 00 10 31 01 FF FF)
12 MN 02/01/08 13:27 MP CS/ZT fault occurred
Fault kind : CS/ZT initial failure (CS/ZT No. = 10)
Data = (01 04 00 10 31 01 FF FF)
12 MN 02/01/08 13:27 MP CS/ZT fault occurred
Fault kind : CS/ZT condition read failure (CS/ZT No. = 10)
Data = (02 04 00 10 31 01 FF FF)
12 MN 02/01/08 13:27 MP CS/ZT fault occurred
Fault kind : CS/ZT condition unmatch (CS/ZT No. = 10)
Data = (03 04 00 10 31 01 FF FF)
12 MN 02/01/08 13:27 MP CS/ZT fault occurred
Fault kind : Bch condition unmatch (CS/ZT No. = 10)
Data = (04 04 00 10 31 01 FF FF)
12 MN 02/01/08 13:27 MP CS/ZT fault occurred
Fault kind : SYS-ID upload failure (CS/ZT No. = 10)
Data = (05 04 00 10 31 01 FF FF)
12 MN 02/01/08 13:27 MP CS/ZT fault occurred
Fault kind : SYS-ID download failure (CS/ZT No. = 10)
Data = (06 04 00 10 31 01 FF FF)
12 MN 02/01/08 13:27 MP CS/ZT fault occurred
Fault kind : CS/ZT make busy failure (CS/ZT No. = 10)
Data = (07 04 00 10 31 FF FF FF)