CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 27 – NWA-008847-001 Rev.3.0
a6ch1001.fm
Example of Fault Occurrence Display using MAT Add-In
Continued on next page
Fault Alarm Date CPU Description
20 MJ 02/01/08 13:28 AP 5 DTI line failure
Remote alarm
Data = (F4 FF FF FF FF FF FF FF)
20 MJ 02/01/08 13:28 AP 5 DTI line failure
Multi remote alarm
Data = (F5 FF FF FF FF FF FF FF)
20 MJ 02/01/08 13:28 AP 5 DTI line failure
S-bit error
Data = (F6 FF FF FF FF FF FF FF)
20 MJ 02/01/08 13:28 AP 5 DTI line failure
CRC error
Data = (F8 FF FF FF FF FF FF FF)
20 MJ 02/01/08 13:28 AP 5 DTI line failure
Slip detected
Data = (F9 FF FF FF FF FF FF FF)
20 MJ 02/01/08 13:28 AP 5 DTI line failure
Main signal all 1
Data = (FA 01 FF FF FF FF FF FF)
20 MJ 02/01/08 13:28 AP 5 DTI line failure
INFO 0
Data = (FB FF FF FF FF FF FF FF)
20 MJ 02/01/08 13:28 AP 5 DTI line failure
INFO 2
Data = (FC FF FF FF FF FF FF FF)
21 MN 02/01/08 13:28 AP 6 DCH/BRT/PRT D-channel link connection failure
(D-ch NO. = 3)
Data = (03 FF FF FF FF FF FF FF)
22 MN 02/01/08 13:28 AP 7 CCH/IPT link connection failure
(CCH/IPT NO. = 3)
Data = (03 FF FF FF FF FF FF FF)
24 MN 02/01/08 13:26 FP 0 Number of faulty trunks was more than predetermined number
Data = (FF FF FF FF FF FF FF FF)
25 MN 02/01/08 13:26 MP Number of lockout stations was more than predetermined number
Data = (FF FF FF FF FF FF FF FF)
26 MN 02/01/08 13:28 FP 1 DLC card down
DLC Failure Kind : Terminal was cut off (Station number = 2000)
Data = (00 00 80 20 00 FF FF FF)
26 MN 02/01/08 13:28 FP 1 DLC card down
DLC Failure Kind : Short circuit (Station number = 2000)
Data = (02 00 80 20 00 FF FF FF)
26 MN 02/01/08 13:28 FP 1 DLC card down
DLC Failure Kind : Ring wire was grounded (Station number = 2000)
Data = (03 00 80 20 00 FF FF FF)
OCTOBER/14/2005
FAULT MESSAGE