CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 29 – NWA-008847-001 Rev.3.0
a6ch1001.fm
Example of Fault Restoration Display using MAT Add-In
Continued on next page
Fault Alarm Date CPU Description
17 - - 04/10/22 13:27 MP Key FD Activation (Center Activation)
Activation OK
Data = (XX XX XX XX XX XX XX XX)
18 - - 02/01/08 13:26 MP FP/AP card returned to normal condition
(FP/AP NO. = 52)
Data = (F4 FF FF FF FF FF FF FF)
19 - - 02/01/08 13:26 MP Power failure returned to normal condition
Recover Kind : AC input failure
Data = (00 01 02 FF FF FF FF FF)
19 - - 02/01/08 13:26 MP Power failure returned to normal condition
Recover Kind : fuse break
Data = (01 02 00 FF FF FF FF FF)
19 - - 02/01/08 13:26 MP Power failure returned to normal condition
Recover Kind : PWR alarm
Data = (02 00 01 FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
PCM loss
Data = (F0 FF FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
Frame loss
Data = (F1 FF FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
Multi frame loss
Data = (F2 FF FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
AIS error
Data = (F3 FF FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
Remote alarm
Data = (F4 FF FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
Multi Remote alarm
Data = (F5 FF FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
S-bit error
Data = (F6 FF FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
CRC error
Data = (F8 FF FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
Slip detected
Data = (F9 FF FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
Main signal all 1
Data = (FA 01 FF FF FF FF FF FF)
30 - - 02/01/08 13:28 AP 5 DTI line returned to normal condition
INFO 0
Data = (FB FF FF FF FF FF FF FF)