EasyManua.ls Logo

NEC NEAX 2000 IPS - Page 83

NEC NEAX 2000 IPS
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 73 – NWA-008847-001 Rev.3.0
a6ch1001.fm
(2) To download the MP program, do the following programming.
DESCRIPTION DATA
For each Site, execute the MP program down-
load and assign the download start time.
(1)
(2)
Y=52
XX00
XX: 00: Main Site No.
01-30: Remote Site No.
0 : Start to download
1 : Now downloading
3 : Not executed
YYYY MM DD HH mm:
Download time
YYYY: 2000-2099 (Year)
MM : 01-12 (Month)
DD : 01-31 (Date)
HH : 00-23 (Hour)
mm : 00-59 (Minute)
CCC : Interrupt downloading/Download
time Clear
NOTE1: You can download the MP programs while the system is operating. The downloaded pro-
gram is stored in flash memory of MP card.
NOTE2: The second data 0 can be set only when the MP program download is not executed (second
data status is 3) and the system data backup is not being executed.
NOTE3: The second data XXXXXXXXXXXX (download time) can be set only when the MP program
download is not executed (second data status is 3) and the system data backup is not being
executed.
NOTE4: While the MP program is being downloaded (second data status is 0), you can input CCC
to interrupt the program download.
If you do that, the second data is changed from 1 (Now downloading) to 3 (Not executed),
and the MP program that has been downloaded disappears.
Execute the MP program download again, if required.
NOTE5: While the MP program is being downloaded (second data status is 0), you cannot input any
command other than CCC. If you do that, “WAIT, BUSY NOW” is displayed.
NOTE6: The download time can be canceled by inputting CCC when the second data
XXXXXXXXXXXX (download time) is displayed.
NOTE7: Execute the changeover of MP program, after the MP program download is completed.
NOTE8: When the communication between Main Site and Remote Site cannot operate normally,
“HARDWARE ERROR” is displayed
START
CM0C
END
JULY/01/2006
MP PROGRAM DOWNLOAD (FTP)