CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 81 – NWA-008847-001 Rev.3.0
a6ch1001.fm
(7) Command output is interrupted if you press “Esc” key while command output is being executed.
When operating from MATWorX, you can interrupt by pressing “Stop MP-FP command print out”
on the Trace screen.
(8) When system initialization is executed in online mode (SW3 of MP card is set to 0), the command
output setting (CMF6 Y=2>03) is cleared and command output is stopped.
(9) All settings assigned by CMF6 Y=2 are initialized if you input CCC for CMF6 Y=2>03.
(10) Output commands can be defined by “Command code”, “FP number”, and “Specification of
particular data”. AND/OR conditions when combining command code (CMF6 Y=2>00, 10, 11, 12),
FP numbers (CMF6 Y=2>01, 20, 21, 22), and specified data (CMF6 Y=2>30, 31, 32, 33) are the
following.
OR : Command is output when a specified condition matches either of two conditions
AND: Command is output when a specified condition matches both of two conditions
CMF6 Y=2 first data
00 10 11 12 01 20 21 22 30 31 32 33
00
OR OR OR AND AND AND AND AND
10
OR OR AND AND AND AND AND
11
OR AND AND AND AND AND
12
AND AND AND AND AND
01
–––– OROROR––––
20
––––– OROR––––
21
–––––– OR––––
22
––––––– ––––
30
–––––––– –––
31
–––––––––
32
––––––––––
33
–––––––––––
CMF6 Y=2 first data