CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 81 – NWA-008847-001 Rev.3.0
a6ch1001.fm
(7) Command output is interrupted if you press “Esc” key while command output is being executed.
When operating from MATWorX, you can interrupt by pressing “Stop MP-FP command print out”
on the Trace screen.
(8) When system initialization is executed in online mode (SW3 of MP card is set to 0), the command
output setting (CMF6 Y=2>03) is cleared and command output is stopped.
(9) All settings assigned by CMF6 Y=2 are initialized if you input CCC for CMF6 Y=2>03.
(10) Output commands can be defined by “Command code”, “FP number”, and “Specification of
particular data”. AND/OR conditions when combining command code (CMF6 Y=2>00, 10, 11, 12),
FP numbers (CMF6 Y=2>01, 20, 21, 22), and specified data (CMF6 Y=2>30, 31, 32, 33) are the
following.
OR : Command is output when a specified condition matches either of two conditions
AND: Command is output when a specified condition matches both of two conditions
CMF6 Y=2 first data
00 10 11 12 01 20 21 22 30 31 32 33
00
OR OR OR AND AND AND AND AND – – –
10
– OR OR AND AND AND AND – AND – –
11
– – OR AND AND AND AND – – AND –
12
– – – AND AND AND AND – – – AND
01
–––– OROROR––––
20
––––– OROR––––
21
–––––– OR––––
22
––––––– ––––
30
–––––––– –––
31
––––––––– ––
32
–––––––––– –
33
–––––––––––
CMF6 Y=2 first data
JULY/01/2006
ONLINE MP-FP COMMAND OUTPUT