EasyManua.ls Logo

NEC NEAX 2000 IPS - Page 99

NEC NEAX 2000 IPS
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 89 – NWA-008847-001 Rev.3.0
a6ch1001.fm
NOTE: To use Hyper Terminal, select File Properties, and set emulation to VT100.
To collect the fault logs and call logs, be sure to set the MP card to on-line mode (set SW3 switch
to 0).
(2) Conditions of fault log collection
By collecting fault logs, you can specify the reset causes and reset time.
By collecting fault logs, you can calculate the number of sending control packets, the number of re-
sending control packets, the number of failed re-sending control packets, the number of received
control packets, the received error control packets, and the error number of control sequences.
The fault logs are collected by the following timing.
- When D
term
IPs or IP-CSs login to the system, and when the IP-PAD card is in online status
- When you set the office data for fault logs collection (CMEA Y=6>11) from MAT/CAT
The output format of fault logs is as follows.
21234567 04/09/13 12:01:40
DATA=1:RESET CAUSE
1=090B09DF 04/09/10 21:40:55 2=090B09DF 04/09/10 21:42:43
3=0644058B 04/09/10 22:13:19 4=09440AE4 04/09/11 08:59:05
5=09440AE4 04/09/11 09:07:23 6=07440A12 04/09/11 09:07:48
7=0644058B 04/09/11 09:11:43 8=0644058B 04/09/11 09:45:29
DATA=2:CONTROL PACKET COUNTER (PROTOCOL=2)
1=00000362 2=00000362 3=00000011 4=00000002
5=00000365 6=00000350 7=00000001
DATA=3:REGISTRATION NG
1=FF-DRS0 2=FF-DRS0 3=FF-DRS0 4=FF-DRS1
5=FF-DRS1 6=FF-DRS1 7=FF-DRS2 8=FF-DRS2
TIME OUT
12
334
3
7
3
8
9
5
6
4 5
JULY/01/2006
VoIP LOG COLLECTION

Table of Contents

Other manuals for NEC NEAX 2000 IPS