Issue 1.0 Spectrum Enterprise
8 SIP Trunk Programming Guide
5. Click Apply.
The SV9300 must be reset in order for the change to take effect.
1. Select SV9300 Main/Remote Unit No. accommodating SIP Trunk
Channels, then click Read to get the current data settings.
2. FD=60 Enter primary DNS server IP Address (optional).
FD=61 Enter secondary DNS server IP Address (optional).
FD=70 Enter global IP Address (optional).
If more than 1 profile is used enter global IP address in CM BA139.
The IP addresses shown are example only and will depend on the network for
the global address and Spectrum Enterprise for DNS specific information.
Command Line Example: Unit 01
CM 0B101>00>192.168.0.210 (Unit 01 VoIP Address)
CM 0B101>01>255.255.255.0 (Unit 01 VoIP Subnet)
CM 0B101>02>192.168.0.1 (Unit 01 VoIP Default GW)
CM 0B101>10>NONE (Default: Location 00)
CM 0B101>36>5061 (Default: SIP Trunk Port 5060)
Figure 4 CM 0B1xx Network Setup (continued)