Issue 1.0
SIP Trunk Programming Guide 11
The SV9300 must be reset in order for the change to take effect.
3.4 SIP Trunk Port Allocation
All values shown are for example purposes only. Your actual values will be
determined by your implementation team.
1. Select SV9300 Main/Remote Unit No. accommodating SIP Trunk
Channels, then click Read to get the current data settings.
2. Enter Trunk Numbers used for the voice channels.
3. Click Apply.
Figure 6 CM 1003 SIP Trunk Port Allocation
Command Line Example: Unit 01
CM 1003>01000>D001 (Unit 01 SIP Trunk Channel 1)
CM 1003>01001>D002 (Unit 01 SIP Trunk Channel 2)
CM 1003>01002>D003 (Unit 01 SIP Trunk Channel 3)
CM 1003>01003>D004 (Unit 01 SIP Trunk Channel 4)