SIP Trunk Programming Guide 19
3.8 SIP Trunk Control Channel Settings
All values shown are for example purposes only. Your actual values will be
determined by your implementation team.
1. Select CCH assigned to SIP trunk and click the Read button to get
current data settings.
2. YY=01 Assign an arbitrary Originating Point Code.
The same originating point code can be used for each SIP trunk server.
3. YY=02 Assign an arbitrary Destination Point Code.
Different destination point code must be used for each SIP trunk server.
4. Click Apply.
Figure 14 CM A7 SIP Trunk Control Channel Settings
Command Line Example:
CM A701>01>00900 (Arbitrary Origination Point Code)
CM A702>01>00901 (Arbitrary Destination Point Code)